JIDI-12 mini centrifuge with high capacity design in leading international idea,with advantage of nice appearance,steady structure and easy handle.This mini centrifuge is really adapt to use in microtubule filtration,fast separate sample,separation of trace blood cells,microbe sample handling and PCR labs separation prevent liquid on the tube side.It is the best chose for handle with less sample.
- Description
| Model No. | JIDI-12A Mini centrifuge |
| Max Speed | 12000rpm |
| Max RCF | 9660×g |
| Capacity | 12X1.5ml/2.0ml,4X8X0.2ml PCR plate rotor |
| Timer | 1-99min |
| Power supply | AC100-220V/50/60Hz |
| Max. power consumption | 45W |
| Noise level | ≤60dB (A) |
| Product weight(not include rotor) | 1.6kg |
| Dimensions(L×W×H) | 194×229×120mm(L×W×H) |
Features:
1.The advanced and reliable PI high-frequency wide-range power control solution is adopted, which conforms to power sources worldwide. Through 16-bit MCU operation, PWM speed regulation enables more precise control of voltage, current, speed, and effective centrifugation time. This ensures extended motor lifespan and reduced electromagnetic noise even in harsh operating environments.
2.Equipped with a reliable and durable DC permanent magnet motor, the speed range is wider at 500 to 12,000 rpm with an accuracy of ±9%. Centrifuge speed increment adjustment is set at 100 rpm, and the effective centrifugation time range is 1-99 minutes or 1-59 seconds.
3.Faster acceleration/deceleration rates allow experiments to be completed in shorter durations.
4.The mainframe and rotor materials are of high strength, resistant to various chemical corrosion, and the rotor has heat-resistant disinfection capabilities.
5.The unique rotor snap-on installation design allows for easy replacement without the need for any tools, making it convenient and quick for laboratory personnel to change rotors.
6.The innovative composite tube rotor head is compatible with various types of tubes, meeting basic experimental needs without the need for rotor replacement.
7.RSS material damping ensures smoother operation, with a rotating space of 360° arc, minimal angle clipping, low wind resistance, minimal temperature rise, and ultra-quiet operation, with machine noise ≤60dB.
8.Features include door protection, overspeed, and imbalance detection systems, enabling real-time monitoring of the centrifugation process to ensure safe operation. When the operation is complete, or if an error or imbalance occurs, an audible signal is emitted, and the operation stops simultaneously, with LCD displaying result codes.
Rotor Accessories
| Rotor | Capacity | Max Speed | Max RCF |
| NO.1 | 1.5/2mlX12 well+PCR 0.2mlX8 well X4 row | 12000 | 9500 |
| NO.2 | PCR 0.2mlX12 well X4 row | 12000 | 5960 |
고객센터안내
전화: 043-215-2012
평일: 09:00 ~ 18:00
휴무: 주말, 공휴일
점심: 12:00 ~ 13:00
*채널톡을 이용해 문의하실 수 있습니다.
배송안내
-기본 배송비는 5,000원이며 상품의 수량, 무게에 따라 배송료는 차등 부과될 수 있습니다.
-주문하신 상품은 결제 후 견적서에 안내드린 납품기한 내 받아보실 수 있습니다. 단, 일요일/법정 공휴일 제외
-주문 폭주, 입고 지연 상품의 경우 미리 안내해드립니다.
교환 및 반품 안내
1. 교환 및 반품 신청 가능 기간
- 상품에 하자가 있는 경우, 상품 수령일로 부터 7일 이내에 교환 및 반품 신청이 가능합니다.
2. 교환 및 반품이 불가능한 경우
- 고객의 단순변심인 경우
- 고객의 부주의로 인한 오 주문일 경우
- 상품 수령 후 7일이 경과한 경우
- 제품의 포장이 훼손되거나 사용 흔적이 있는 경우
- 고객의 부주의로 인해 상품이 훼손된 경우
- 주문 제작 상품, 맞춤형 제품 등 판매가 불가능한 상품인 경우
- 반품 또는 교환 요청 시점에서 제품의 구성품이 누락된 경우
- Description
| Model No. | JIDI-12A Mini centrifuge |
| Max Speed | 12000rpm |
| Max RCF | 9660×g |
| Capacity | 12X1.5ml/2.0ml,4X8X0.2ml PCR plate rotor |
| Timer | 1-99min |
| Power supply | AC100-220V/50/60Hz |
| Max. power consumption | 45W |
| Noise level | ≤60dB (A) |
| Product weight(not include rotor) | 1.6kg |
| Dimensions(L×W×H) | 194×229×120mm(L×W×H) |
Features:
1.The advanced and reliable PI high-frequency wide-range power control solution is adopted, which conforms to power sources worldwide. Through 16-bit MCU operation, PWM speed regulation enables more precise control of voltage, current, speed, and effective centrifugation time. This ensures extended motor lifespan and reduced electromagnetic noise even in harsh operating environments.
2.Equipped with a reliable and durable DC permanent magnet motor, the speed range is wider at 500 to 12,000 rpm with an accuracy of ±9%. Centrifuge speed increment adjustment is set at 100 rpm, and the effective centrifugation time range is 1-99 minutes or 1-59 seconds.
3.Faster acceleration/deceleration rates allow experiments to be completed in shorter durations.
4.The mainframe and rotor materials are of high strength, resistant to various chemical corrosion, and the rotor has heat-resistant disinfection capabilities.
5.The unique rotor snap-on installation design allows for easy replacement without the need for any tools, making it convenient and quick for laboratory personnel to change rotors.
6.The innovative composite tube rotor head is compatible with various types of tubes, meeting basic experimental needs without the need for rotor replacement.
7.RSS material damping ensures smoother operation, with a rotating space of 360° arc, minimal angle clipping, low wind resistance, minimal temperature rise, and ultra-quiet operation, with machine noise ≤60dB.
8.Features include door protection, overspeed, and imbalance detection systems, enabling real-time monitoring of the centrifugation process to ensure safe operation. When the operation is complete, or if an error or imbalance occurs, an audible signal is emitted, and the operation stops simultaneously, with LCD displaying result codes.
Rotor Accessories
| Rotor | Capacity | Max Speed | Max RCF |
| NO.1 | 1.5/2mlX12 well+PCR 0.2mlX8 well X4 row | 12000 | 9500 |
| NO.2 | PCR 0.2mlX12 well X4 row | 12000 | 5960 |
고객센터안내
전화: 043-215-2012
평일: 09:00 ~ 18:00
휴무: 주말, 공휴일
점심: 12:00 ~ 13:00
*채널톡을 이용해 문의하실 수 있습니다.
배송안내
-기본 배송비는 5,000원이며 상품의 수량, 무게에 따라 배송료는 차등 부과될 수 있습니다.
-주문하신 상품은 결제 후 견적서에 안내드린 납품기한 내 받아보실 수 있습니다. 단, 일요일/법정 공휴일 제외
-주문 폭주, 입고 지연 상품의 경우 미리 안내해드립니다.
교환 및 반품 안내
1. 교환 및 반품 신청 가능 기간
- 상품에 하자가 있는 경우, 상품 수령일로 부터 7일 이내에 교환 및 반품 신청이 가능합니다.
2. 교환 및 반품이 불가능한 경우
- 고객의 단순변심인 경우
- 고객의 부주의로 인한 오 주문일 경우
- 상품 수령 후 7일이 경과한 경우
- 제품의 포장이 훼손되거나 사용 흔적이 있는 경우
- 고객의 부주의로 인해 상품이 훼손된 경우
- 주문 제작 상품, 맞춤형 제품 등 판매가 불가능한 상품인 경우
- 반품 또는 교환 요청 시점에서 제품의 구성품이 누락된 경우




켐코코리아(주) 개인정보 보호책임자: David Kim